2.4 Location The machine should be kept away from flammable and explosive materials, as well as from sunlight and intense light. The machine should be placed in a well-ventilated location. The machine must be set up on sufficiently firm ground, if necessary, according to the minimum requirements of the information given in the foundation plan. In addition to the ground conditions, the guidelines and instructions of the accident prevention regulations as well as the workplace regulations must be observed when selecting an installation site. When assembling on floor coverings, check their load-bearing capacity. A construction expert should be consulted for inspection when mounting on floor coverings. The machine should only be mounted and used within closed rooms. It has no corresponding safety features (e.g. IP protection, galvanised design, etc.). Temperature 4-40 °C Sea level < 1500 m Humidity 50% at 40 °C – 90% at 20 °C Drawing ® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-09 Manufacturer ATH-Heinl GmbH & CO.KG - 15 -
2.5 Fixing General and local regulations must be observed. Therefore, these steps should only be carried out by a trained professional. The machine must be set up and fixed on sufficiently firm ground, if necessary, according to the minimum requirements of the information given in the foundation plan. The machine must be fastened at the points provided with suitable or specified fastening material. In addition to the ground conditions, the guidelines and instructions of the accident prevention regulations as well as the workplace regulations must be observed when selecting an installation site. When assembling on floor coverings, check their load-bearing capacity. A construction expert should be consulted for inspection when mounting on floor coverings. 2.6 Electrical Connection General and local regulations must be observed. Therefore, these steps may only be carried out by a trained professional. Pay attention to the necessary supply line (see technical data). The connection should be made with a 230V Schuko plug or 5-phase 16 A CEE plug (partially included). Voltage deviations should be 0.9 - 1.1 times the nominal voltage range and the frequency deviation should be 0.99 - 1.01 times the frequency range. Necessary protective measures must be taken to guarantee this. At the end of the work, the direction that the motor rotates must be checked. 2.7 Pneumatic Connection For all pneumatic systems, a compressed air maintenance unit (partially included) must be installed between the supply line and the system. The air pressure of the supply line must at least correspond to the technical data. The compressed air maintenance unit must be set correctly and checked. The compressed air maintenance unit must be serviced at regular intervals. The maximum or minimum pressure ensures perfect functioning without any damage. ® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-09 Manufacturer ATH-Heinl GmbH & CO.KG - 16 -
Deutsch English Polskie Français
Inhalt 1.0 EINLEITUNG .............
1.2 Beschreibung Abdeckung oben Um
1.3 Bedienung Taster Heben um Hebeb
Sicherheitshinweise 1. Achten Sie a
Traglastverteilung Q Gesamtgewicht
® Urheberrecht ATH-Heinl GmbH & CO
2.3 Lieferumfang Transportbox mit:
2.3 Livraison Caisse de transport a
2.5 Fixation Il convient ici de res
2.9 Montage Ce manuel ne doit pas
Installation de l'alimentation Plac
Raccordement de la ligne hydrauliqu
2.10 Travaux finaux Avant la mise e
Vérifier le bon fonctionnement de
3.0 EXPLOITATION 3.1 Manuel d'utili
4.0 MAINTENANCE Afin de garantir le
4.3 Remarques Quel que soit l'état
Problèmes lors de l'abaissement Le
4.7 Élimination • Coupez l'alime
6.0 ANNEXE 6.1 Schéma pneumatique
6.3 Schéma hydraulique 1 Filtre à
7.1 Étendue de la garantie produit
8.1 Procès-verbal d'installation e
8.3 Contrôle visuel (personne qual
Contrôle visuel (personne qualifi
9.0 NOTICES ® Droit d'auteur ATH-H
www.ath-heinl.de ATH-Heinl GmbH & C
Spis treści 1.0 WPROWADZENIE .....
1.2 Opis Pokrywa na górze Aby zakr
1.3 Obsługa Przycisk podnoszenia p
Instrukcje bezpieczeństwa 1. Zwró
Rozkład obciążenia Q Całkowita
® Prawa autorskie ATH-Heinl GmbH &
2.3 Zakres dostawy Skrzynia transpo
2.5 Mocowanie W tym przypadku nale
2.9 Montaż Niniejszej instrukcji n
Instalacja zasilacza Umieść zasil
Podłączenie linii hydraulicznej U
2.10 Prace końcowe Przed uruchomie
Sprawdź, czy wyłącznik krańcowy
3.0 PRACA 3.1 Instrukcja eksploatac
4.0 KONSERWACJA Aby zapewnić bezpi
4.3 Wskazówki Bez względu na zani
Problemy z opuszczaniem Winda sama
4.7 Utylizacja • Odłączyć dop
6.0 ZAŁĄCZNIK 6.1 Schemat obwodu
6.3 Schemat obwodu hydraulicznego 1
7.1 Zakres gwarancji produktu • P
8.1 Protokół ustawiania i przekaz
8.3 Kontrola wzrokowa (upoważniona
Kontrola wzrokowa (upoważniona oso
9.0 NOTIZEN ® Prawa autorskie ATH-
www.ath-heinl.de ATH-Heinl GmbH & C